Products > Telecommunication > Cable > Optical Cable

  • Loose Tube Cable for Aerial_ADSS Type II

    가공용 루즈튜브 광케이블_ADSS 타입 II

  • Domestic :+82-31-450-3957jbs790708@taihan.com
  • Overseas :+82-31-450-3721terry@taihan.com
  • Email Page
  • Print Page

SEND TO MAIL

DO YOU HAVE ANY QUESTIONS?

71e420669b2bb0a4f4ead41c23e9dea3_1469950
  • 1. Optical fiber : Single mode optical fiber(SMF), multi mode optical fiber(MMF), non-zero dispersion shifted optical fiber(NZ-DSF)
  • 2. Central strength member : Galvanized steel wire or fiber reinforced plastic(FRP) - ADSS type : FRP
  • 3. Moisture barrier : Water blocking jelly filling compound of water blocking yarn
  • 4. Loose tube : Thermoplastic material(polybutylene terephthalate)
  • 5. Filler : Polyethylene string
  • 6. Wrapping tape : Non-hygroscopic plastic tape or water blocking tape
  • 7. Armored layer : Aramid yarn(Lashing aerial type : steel tape)
  • 8. Outer sheath : Black polyethylene

Feature

  • - Standard fiber count : 2~144 fibers
  • - Excellent mechanical and environmental performance
  • - Protection from lighting and electrical interference
  • - Dry or jelly filled type

Application

  • - Small diameter and light weight
  • - Subscriber network system
  • - Long haul communication system

Cable Specification

No. of fibers Per tube No. of fibers Outer dia.(mm (in)) Cable wt.(kg/km (lb/1000ft))
6 2~30 11.7 (0.46) 100 (67)
12 36~60 12.3 (0.48) 110 (74)
12 62~72 12.5 (0.49) 115 (77)
12 74~96 14.0 (0.55) 145 (97)
12 98~120 15.6 (0.61) 180 (121)
12 122~144 17.2 (0.68) 215 (144)

Mechanical & Environmental Characteristic

Classification Unit Specification
Allowable tensile strength kgf (lbf) 150~600 (331~1323)
Crush resistance kgf/cm (lbf/in) 20 (44)
Minimum bending diameter_Dynamic mm (in) 20 times of cable diameter
Minimum bending diameter_Static mm (in) 10 times of cable diameter
Operating temperature range ℃ (℉) -40~+70 (-40~+158)
Delivery length km (1000ft) 1~6 (3.3~19.7)

Ordering Guide

34f6441bbb35dc3c8e575d9e8586c663_1471401
Product Line 1. Brand Name 2. Cable Type 3. Fiber Count 4. Fiber Type
Classification Description Classification Description Classification Description Classification Description Classification Description
OC Outdoor Optical Cable MOCA Mini Optical Cable 01 Multi LT 072 72 B1 G.652.B
    RHONE Loose Tube Cable for Duct 02 Central LT 096 96 D1 G.652.D
    TICI Loose Tube Cable for Direct Buried 03 Multi Ribbon Tube 144 144 D2 G.652.D(200μm)
    ROCK I Loose Tube Cable for ADSS Type I 04 Central Ribbon Tube 216 216 N1 G.655.C
    ROCK II Loose Tube Cable for ADSS Type II     288 288 N2 G.655.A(L)
    FIEIT Loose Tube Cable for Fig. 8 Type         N3 G.655.A(S)
    COX Loose Tube Cable for CATV Network         M1 OM1(62.5μm)
    HICO Loose Tube Cable for High-Count         M2 OM2(50.0μm)
    TRASI Ribbon Tube Cable         M3 OM3(50.0μm)
    CANN Air Blown Cable         M4 OM4(50.0μm)
                I1 G.657.A1
                I2 G.657.A2
                I3 G.657.B3
                LL Low Loss
                C1 D1 and N1
                C2 D1 and N2
                C3 D1 and N3
5. Fiber Placement 6. Performance Option Code 7. Jacket Layer 8. Central Strength Member 9. Strength Material
Classification Description Classification Description Classification Description Classification Description Classification Description
002 2 F / LT 01 0.40/-/0.30 dB/km (G.652.B) SN Single Jacket Non-Armored N None N0 None
004 4 F / LT 02 0.35/-/0.25 dB/km (G.652.B) SS Single Jacket Single-Armored F FRP(Fiber Reinforced Plastic) GY Glass Yarn
006 6 F / LT 03 0.36/-/0.22 dB/km (G.652.B) DN Double Jacket Non-Armored S Steel Wire AY Aramid Yarn
008 8 F / LT 11 0.40/0.40/0.30 dB/km (G.652.D) DS Double Jacket Single-Armored     FR FRP Rod
012 12 F / LT 12 0.35/0.35/0.25 dB/km (G.652.D) DD Double Jacket Double-Armored     SR Steel Wire Rod
024 24 F / LT 13 0.36/0.36/0.22 dB/km (G.652.D) TD Triple Jacket Double-Armored        
072 72 F / RT 21 -/-/0.30 dB/km (G.655.C/A(L)/A(S))            
144 144 F / RT 22 -/-/0.25 dB/km (G.655.C/A(L)/A(S))            
    23 -/-/0.22 dB/km (G.655.C/A(L)/A(S))            
    31 0.40/0.40/0.30 dB/km (G.657.A1/A2/B3)            
    32 0.35/0.35/0.25 dB/km (G.657.A1/A2/B3)            
    33 0.36/0.36/0.22 dB/km (G.657.A1/A2/B3)            
    41 3.5/1.5 dB/km (OM1/OM2/OM3/OM4)            
    42 3.4/1.0 dB/km (OM1/OM2/OM3/OM4)            
    43 3.0/1.0 dB/km (OM2/OM3/OM4)            
    51 0.34/0.20 dB/km (Low Loss)            
10. Armoring or Moisture Barrier Material 11. Water Bloking Type 12. Jacket Material 13. Length Marking 14. Define Special Requirements
Classification Description Classification Description Classification Description Classification Description Classification Description
N0 None A All Dry Z1 Low Density Polyethylene 1 Markings in Meter 00 No Special Requirement
ST Corrugated Steel Tape S Semi Dry(Tube with Gel-Filled) Z2 Medium Density Polyethylene 2 Markings in Feet 01 Non-Metallic and Rodent Protection
SW Steel Wire F Fully Gel-Filled Z3 High Density Polyethylene     02 Termite Protection
LA Laminated Aluminium Tape     ZV Polyvinyl Chloride        
C1 LA and ST     F0 Flame Retardant Polyethylene with LSZH        
C2 LA and SW     TR Track Resistant        

Part No. List

Part No. 1. Brand Name 3. Fiber Count 7. Jacket Layer 11. Water Bloking Type
OC-ROCK II-xx-072-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 072 Single Jacket Non-Armored All Dry
OC-ROCK II-xx-096-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 096 Single Jacket Non-Armored All Dry
OC-ROCK II-xx-144-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 144 Single Jacket Non-Armored All Dry
OC-ROCK II-xx-216-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 216 Single Jacket Non-Armored All Dry
OC-ROCK II-xx-288-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 288 Single Jacket Non-Armored All Dry
OC-ROCK II-xx-072-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 072 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-096-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 096 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-144-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 144 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-216-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 216 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-288-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 288 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-072-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 072 Double Jacket Non-Armored All Dry
OC-ROCK II-xx-096-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 096 Double Jacket Non-Armored All Dry
OC-ROCK II-xx-144-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 144 Double Jacket Non-Armored All Dry
OC-ROCK II-xx-216-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 216 Double Jacket Non-Armored All Dry
OC-ROCK II-xx-288-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for ADSS Type II 288 Double Jacket Non-Armored All Dry
OC-ROCK II-xx-072-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 072 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-096-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 096 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-144-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 144 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-216-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 216 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-ROCK II-xx-288-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for ADSS Type II 288 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)

※ If it is not there, see the ordering guide.