Products > Telecommunication > Cable > Optical Cable

  • Loose Tube Cable for Duct

SEND TO MAIL

DO YOU HAVE ANY QUESTIONS?

71e420669b2bb0a4f4ead41c23e9dea3_1469947
  • 1. Optical fiber : Single mode optical fiber(SMF), multi mode optical fiber(MMF), non-zero dispersion shifted optical fiber(NZ-DSF)
  • 2. Central strength member : Galvanized steel wire or fiber reinforced plastic(FRP)
  • 3. Moisture barrier 1 : Water blocking jelly filling compound of water blocking yarn
  • 4. Loose tube : Thermoplastic material(polybutylene terephthalate)
  • 5. Filler : Polyethylene string
  • 6. Wrapping tape : Non-hygroscopic plastic tape or water blocking tape(optional)
  • 7. Moisture barrier 2 : Laminated aluminum tape(optional)
  • 8. Sheath : Black polyethylene
  • 9. Non-metal strength member : Glass yarn or aramid yarn

Feature

  • - Standard fiber count : 2~312 fibers
  • - Excellent mechanical and environmental performance
  • - Anti-termite treatment(optional)
  • - Excellent optical performance
  • - High tensile strength design
  • - Dry or jelly filled type

Application

  • - Local area network(LAN)
  • - Subscriber network system
  • - Long haul communication system

Cable Specification

Classification No. of fibers Per tube No. of fibers Outer dia.(mm (in)) Cable wt.(kg/km (lb/1000ft))
Dry type 6 2~36 10.5 (0.41) 90 (60)
Dry type 12 48~72 11.1 (0.44) 102 (69)
Dry type 12 74~96 12.5 (0.49) 130 (87)
Dry type 12 98~120 13.9 (0.55) 158 (106)
Dry type 12 122~144 15.5 (0.61) 195 (131)
Dry type 12 288 18.2 (0.72) 253 (170)
Dry type 12 312 19.0 (0.75) 276 (185)
Jelly filled type 6 2~36 10.9 (0.43) 122 (82)
Jelly filled type 12 48~72 11.5 (0.45) 136 (91)
Jelly filled type 12 74~96 12.8 (0.50) 142 (95)
Jelly filled type 12 98~120 14.2 (0.56) 174 (117)
Jelly filled type 12 122~144 15.8 (0.62) 214 (144)
Jelly filled type 12 288 18.5 (0.73) 341 (229)
Jelly filled type 12 312 19.3 (0.76) 374 (251)

Mechanical & Environmental Characteristic

Classification Unit Specification
Allowable tensile strength kgf (lbf) Dry type : 135~450 (298~992)
Allowable tensile strength kgf (lbf) Jelly filled type : 180~550 (397~1213)
Crush resistance kgf/cm (lbf/in) 20 (44)
Minimum bending diameter_Dynamic mm (in) 20 times of cable diameter
Minimum bending diameter_Static mm (in) 10 times of cable diameter
Operating temperature range ℃ (℉) -40~+70 (-40~+158)
Delivery length km (1000ft) 1~6 (3.3~19.7)

Ordering Guide

71e420669b2bb0a4f4ead41c23e9dea3_1469946
Product Line 1. Brand Name 2. Cable Type 3. Fiber Count 4. Fiber Type
Classification Description Classification Description Classification Description Classification Description Classification Description
OC Outdoor Optical Cable MOCA Mini Optical Cable 01 Multi LT 072 72 B1 G.652.B
    RHONE Loose Tube Cable for Duct 02 Central LT 096 96 D1 G.652.D
    TICI Loose Tube Cable for Direct Buried 03 Multi Ribbon Tube 144 144 D2 G.652.D(200μm)
    ROCK I Loose Tube Cable for ADSS Type I 04 Central Ribbon Tube 216 216 N1 G.655.C
    ROCK II Loose Tube Cable for ADSS Type II     288 288 N2 G.655.A(L)
    FIEIT Loose Tube Cable for Fig. 8 Type         N3 G.655.A(S)
    COX Loose Tube Cable for CATV Network         M1 OM1(62.5μm)
    HICO Loose Tube Cable for High-Count         M2 OM2(50.0μm)
    TRASI Ribbon Tube Cable         M3 OM3(50.0μm)
    CANN Air Blown Cable         M4 OM4(50.0μm)
                I1 G.657.A1
                I2 G.657.A2
                I3 G.657.B3
                LL Low Loss
                C1 D1 and N1
                C2 D1 and N2
                C3 D1 and N3
5. Fiber Placement 6. Performance Option Code 7. Jacket Layer 8. Central Strength Member 9. Strength Material
Classification Description Classification Description Classification Description Classification Description Classification Description
002 2 F / LT 01 0.40/-/0.30 dB/km (G.652.B) SN Single Jacket Non-Armored N None N0 None
004 4 F / LT 02 0.35/-/0.25 dB/km (G.652.B) SS Single Jacket Single-Armored F FRP(Fiber Reinforced Plastic) GY Glass Yarn
006 6 F / LT 03 0.36/-/0.22 dB/km (G.652.B) DN Double Jacket Non-Armored S Steel Wire AY Aramid Yarn
008 8 F / LT 11 0.40/0.40/0.30 dB/km (G.652.D) DS Double Jacket Single-Armored     FR FRP Rod
012 12 F / LT 12 0.35/0.35/0.25 dB/km (G.652.D) DD Double Jacket Double-Armored     SR Steel Wire Rod
024 24 F / LT 13 0.36/0.36/0.22 dB/km (G.652.D) TD Triple Jacket Double-Armored        
072 72 F / RT 21 -/-/0.30 dB/km (G.655.C/A(L)/A(S))            
144 144 F / RT 22 -/-/0.25 dB/km (G.655.C/A(L)/A(S))            
    23 -/-/0.22 dB/km (G.655.C/A(L)/A(S))            
    31 0.40/0.40/0.30 dB/km (G.657.A1/A2/B3)            
    32 0.35/0.35/0.25 dB/km (G.657.A1/A2/B3)            
    33 0.36/0.36/0.22 dB/km (G.657.A1/A2/B3)            
    41 3.5/1.5 dB/km (OM1/OM2/OM3/OM4)            
    42 3.4/1.0 dB/km (OM1/OM2/OM3/OM4)            
    43 3.0/1.0 dB/km (OM2/OM3/OM4)            
    51 0.34/0.20 dB/km (Low Loss)            
10. Armoring or Moisture Barrier Material 11. Water Bloking Type 12. Jacket Material 13. Length Marking 14. Define Special Requirements
Classification Description Classification Description Classification Description Classification Description Classification Description
N0 None A All Dry Z1 Low Density Polyethylene 1 Markings in Meter 00 No Special Requirement
ST Corrugated Steel Tape S Semi Dry(Tube with Gel-Filled) Z2 Medium Density Polyethylene 2 Markings in Feet 01 Non-Metallic and Rodent Protection
SW Steel Wire F Fully Gel-Filled Z3 High Density Polyethylene     02 Termite Protection
LA Laminated Aluminium Tape     ZV Polyvinyl Chloride        
C1 LA and ST     F0 Flame Retardant Polyethylene with LSZH        
C2 LA and SW     TR Track Resistant        

Part No. List

Part No. 1. Brand Name 3. Fiber Count 7. Jacket Layer 11. Water Bloking Type
OC-RHONE-xx-072-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 072 Single Jacket Non-Armored All Dry
OC-RHONE-xx-096-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 096 Single Jacket Non-Armored All Dry
OC-RHONE-xx-144-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 144 Single Jacket Non-Armored All Dry
OC-RHONE-xx-216-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 216 Single Jacket Non-Armored All Dry
OC-RHONE-xx-288-xx-xxx-xx-SN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 288 Single Jacket Non-Armored All Dry
OC-RHONE-xx-072-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 072 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-MOCA-xx-096-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 096 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-144-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 144 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-216-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 216 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-288-xx-xxx-xx-SN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 288 Single Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-072-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 072 Double Jacket Non-Armored All Dry
OC-RHONE-xx-096-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 096 Double Jacket Non-Armored All Dry
OC-RHONE-xx-144-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 144 Double Jacket Non-Armored All Dry
OC-RHONE-xx-216-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 216 Double Jacket Non-Armored All Dry
OC-RHONE-xx-288-xx-xxx-xx-DN-x-xx-xx-A-xx-x-xx Loose Tube Cable for Duct 288 Double Jacket Non-Armored All Dry
OC-RHONE-xx-072-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 072 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-096-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 096 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-144-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 144 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-216-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 216 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)
OC-RHONE-xx-288-xx-xxx-xx-DN-x-xx-xx-S-xx-x-xx Loose Tube Cable for Duct 288 Double Jacket Non-Armored Semi Dry(Tube with Gel-Filled)

※ If it is not there, see the ordering guide.